A tankless water heater is a different machine from a storage tank, and it fails differently. There is no tank to leak, but there is a heat exchanger that scales, a flow sensor that decides when to fire, an ignition system, and a venting category that is often specific to the model. The unit also tells you what it thinks is wrong: almost every tankless fault produces an error code.
What the error code is telling you
A tankless controller reports the condition that stopped it, not necessarily the part that failed. Codes cluster into four groups: ignition and flame, water flow, temperature limit, and venting or air pressure. A flow code can mean a closed valve, a clogged inlet screen, a failed flow sensor or scale in the exchanger. An ignition code can mean gas supply, igniter, flame sensor or condensate.
That is why reading the code is the first step and replacing the part it names is not. The same code has several causes, and the cheapest one is often not the part.
Scale, and why hard water matters here
A tankless heat exchanger passes water through narrow channels. Scale narrows them, which reduces flow and heat transfer, and the unit responds by limiting output or shutting down. Irvine's supply blends local groundwater with harder imported water, so the descaling interval is shorter than a soft-water city's.
Descaling is not a cosmetic service. It is circulated through the exchanger to dissolve the mineral layer, and skipping it is what turns a maintenance item into a repair. A unit that has run years without it may need more than one pass, and a badly scaled exchanger can be past cleaning.
Flow and temperature faults
Tankless units activate above a minimum flow rate. A showerhead that has been changed for a low-flow model, a partially closed valve, a clogged aerator or a filter screen can all drop flow below that threshold, and the unit either fails to fire or cycles off mid-shower. A temperature limit fault can come from scale, from a mixing valve, or from an incoming water temperature the unit cannot raise enough at the flow being asked for.
Ignition, gas and venting
Gas tankless units need adequate gas volume, which is why a conversion from a tank sometimes needs the gas line upgraded. Condensing units produce condensate that must drain, and a blocked or frozen condensate line will shut the unit down. Venting has to match the model's category, and a flue installed for a different appliance is a common cause of pressure-switch faults.
Repair or replace
A sensor, igniter, mixing valve or control board is a repair. A heat exchanger that has failed or is heavily scaled, on a unit approaching the end of its life, is usually not worth replacing on its own. Tankless units can reach roughly twenty years with regular descaling; one that has had none and is already throwing scale codes is closer to the end than its age suggests.
What the visit needs
The model number, the code history, and a description of when hot water fails: every tap, one fixture, or only when two are running. That last detail separates a unit fault from a flow problem, and it costs nothing to note before calling.