A tankless unit in the valley has one operating condition the coastal units do not: sustained summer heat, both outside and in the space where it hangs.
Codes as systems
Flow: a closed valve, a blocked screen, a frozen sensor, or scale. Ignition: gas volume, igniter, flame sensor, condensate. Temperature: a probe out of range or a mixing valve. Venting: a blocked termination or a pressure switch that will not prove.
Heat
High ambient temperature derates the unit, and venting has less margin. A lockout that begins during a hot spell and clears at night is describing conditions rather than a failed part.
Flow
Minimum activation flow matters: one low-flow tap may not start the unit while another fixture will.
Scale
Without a measured hardness here, descaling runs on the maker's interval and the unit's behaviour at a known flow.
Before the visit
Model, code, fuel, and when the fault first appeared.