Tankless units in Kathryn sit in renovations and newer attached homes, usually on a wall where the flue run is short.
Codes are symptoms
The controller names the system that stopped the unit. Flow can mean a shut valve, a blocked screen, a sensor or scale in the exchanger; ignition can mean gas volume, an igniter, a sensor or a blocked condensate. The part is found from there rather than from the code alone.
Scale on district water
Irvine's supply comes from the district, and part of it is hard imported water. The exchanger passages are narrow, so minerals close them: flow drops, heat transfer drops, faults follow. Descaling circulates a weak acid through the exchanger from the service valves.
Flow thresholds
Units activate above a minimum flow. One aerator or a half-closed valve can sit below it, and the appliance never lights. Cleaning the screen and the aerators comes before any part.
Venting and gas
A short flue still needs its listed clearance and a cap that drafts. A gas supply sized for a storage tank may not deliver the input the burner asks for at ignition — an installation question, settled before a board is replaced.
Before the visit
The code, the model, and which fixture triggers it.