Tankless units here turn up in renovations and newer builds, and they meet a household that is larger than the coastal average: 2.9 people, often drawing two fixtures at once.
Capacity before components
A tankless unit raises the incoming water temperature at the flow it is given. Two showers plus a laundry can exceed that at any one time, and the unit limits output rather than failing. If the complaint is "it cuts out when everyone showers", the answer is the flow and the model's rating, not a sensor.
Scale
IRWD serves almost all of Lake Forest, and part of that supply is hard imported water. The exchanger passages are narrow, so minerals narrow them further: flow drops, heat transfer drops, faults follow. Descaling runs a weak acid through the exchanger from the service valves.
Codes
The controller names the system — flow, ignition, temperature, venting — not the part. A flow fault might be a shut valve, a blocked screen, a sensor or scale; an ignition fault might be gas volume, an igniter, a sensor or condensate.
Venting
Inland installations are less exposed than coastal ones, but a flue still needs its listed clearance and a termination that drafts. A blocked condensate line stops a condensing unit outright.
Repair or replace
Sensors, igniters, valves and boards are repairs. A dead exchanger on an ageing unit rarely justifies fitting just that part.
Before the visit
The code, the model, and whether one tap or several triggers it.