Tankless units in Aliso appear in renovated homes and newer townhomes, and they carry the same three pressures as anywhere in the district: gas volume, venting, and the hardness of the water.
What the code tells you
The controller reports the condition that stopped it, not the component. A flow code can mean a closed valve, a blocked inlet screen, a failing sensor or a scaled exchanger; an ignition code can mean gas volume, igniter, sensor or condensate. So treat the code as where the diagnosis opens, not as a part number.
Gas volume
The burner demands high input the moment a tap opens. A supply sized for a storage tank, or a run shared with a range and a dryer, may not deliver that volume, and the unit fails to establish flame. Correcting the gas line is installation work, and it is worth establishing before a control board is replaced.
Scale
The exchanger's channels are narrow and the district's imported water deposits on them. Flow drops, heat transfer drops, and the unit limits output or shuts down. Descaling pushes a mild acid through the exchanger from the service valves; where those were never fitted, adding them is part of the job.
Flow and temperature
Units activate above a minimum flow. A low-flow showerhead, a partly closed valve, a clogged aerator or a blocked inlet screen can fall below it. Temperature limits come from scale, a mixing valve, or incoming water too cold to lift at the flow being asked for.
Repair or replace
Sensors, igniters, mixing valves and boards are ordinary repairs. A failed or badly scaled exchanger on a unit near the end of its service life usually is not worth replacing alone. Descaling regularly is what gets these units to roughly twenty years.
Before the visit
Model number, which codes have appeared, and whether every tap runs cold or only one.