Gas units on this coast sit in garages where the lot allows, in utility rooms, and sometimes in semi-exposed spaces that are a local habit rather than a universal one. The ignition faults are ordinary. What is not ordinary is the condition of the hardware around them.
Ignition, in the usual order
The pilot or igniter lights the burner, and a sensing element proves it. Failures come from an aged thermocouple, a fouled pilot, a coated sensor, or a valve that will not stay open. The gas supply and shut-off valve are confirmed first, because a partly closed valve imitates all four.
The coastal complication
Sea air works on the vent before it works on the heater. Caps pit, fasteners seize, and a termination that was fine inland starts disturbing the draft. When a unit lights and then drops out on a windy day, the flue is the first place to look rather than the last.
Wind-driven rain adds its own failure: water into a termination that was capped for the wrong exposure.
Air
A semi-exposed space still needs the combustion air its listing calls for. Stored paint, solvents or garden chemicals near the unit can starve the flame or trip a vapour-sensing shutoff, and the reset will not hold until the cause is gone.
What the visit covers
Supply and valve, ignition circuit, burner, air path, flue and termination, controls. The repair follows from what fails: a thermocouple, an igniter, a sensor, a valve, a cleaned burner, or a vent correction.
Work on the gas piping, the regulator or the meter belongs to a licensed gas contractor, not to a heater call.
Repair or replace
On the coast, a vent that has failed while the tank is sound is a repair. A tank that has gone at a seam with a vent on its last legs is a replacement, and the City of Newport Beach permit comes with it.