Gas is still the ordinary fuel for storage tanks across Irvine, and a Browning address follows the same sequence of checks as anywhere else in the city.
Sequence
Confirm other gas appliances work. Light the pilot and watch whether it holds. Where it holds, look at the burner: a lazy flame, a roar or a lift each point somewhere different. Then the flue.
The three circuits
Gas volume — meter, regulator, shut-off, pipe size. Ignition — pilot or igniter, orifice, sensing element. Air — combustion air, the burner's ports, and whether the closet door or a stored box is blocking it.
Venting and safety
A flue at less than its listed clearance, a termination that recirculates, or soot on the draft hood means the unit stays off until corrected. Carbon monoxide is not a symptom to wait on.
Parts
Thermocouple, igniter, thermopile, gas valve, pilot assembly. A valve is replaced when it will not open or will not stay open, and the supply has been proved first.
Gas piping and the meter are a licensed gas contractor's work.