A Como gas tank usually lives in a garage corner, and the corner is often fuller than it should be. That matters for two reasons: combustion air, and the vapours that can trip a modern unit's safety shutoff.
Ignition
The pilot or igniter lights the burner; a sensing element proves the flame. When it does not hold, the causes are narrow: an aged thermocouple, a fouled pilot, a coated flame sensor, a gas valve that will not stay open, or a flame too weak to satisfy the sensor. Replacing the part without checking whether the flame reaches it is the usual wasted visit.
Air and vapours in a crowded corner
Gas units need air. A corner packed with paint cans, solvents, a mower and a fuel can both restricts the air path and supplies exactly the vapours a flammable-vapour-resistant unit is designed to shut off for. Once tripped, the unit will not relight until the cause is removed and the device is reset as the manufacturer instructs — resetting it in the same air produces the same trip.
The short flue
Compact garages here often have a short flue run and a low ceiling. Clearance to combustibles, a termination that works with the building's pressure, and a flue without a sag all matter more when the run is short. Soot at the base or an exhaust smell in the garage is a stop-use finding, not a tune-up note.
What the visit covers
Supply and shut-off valve, ignition circuit, burner and air path, flue and termination, controls. The repair follows: thermocouple, igniter, sensor, valve, cleaning, or a flue correction.
Gas piping, the regulator and the meter are licensed gas work, outside the scope of a service call.
Repair or the newer tank