A newer house is not a guarantee of a correct installation. On this stock the faults are ordinary gas faults, and the sequence that finds them does not change.
Supply
Other appliances first. A part-closed valve or a regulator fault presents exactly as a dead thermocouple, and one working hob rules it out in seconds.
Ignition
Pilot or igniter, the orifice, the sensing element and its connection. A flame that lights and dies within seconds is describing the sensing circuit rather than the gas.
Burner and air
Ports blocked, air starved, or a flame lifting off the burner. In a large utility space the air is usually fine; the trap is a shroud or a shelf added later.
Venting
The flue at its listed clearance, sloping correctly, terminating where it drafts. A short run through a finished wall still has to meet the listing.
The part
Thermocouple, igniter, thermopile, gas valve — after the supply is proved.
Gas piping and the meter remain a licensed gas contractor's work.