Installation in a coastal city has one extra design input: salt. Everything else — clearances, air, discharge — is the same work done properly.
Venting
Follow the listing's clearances, then think about where the termination lands. A flue facing the prevailing onshore breeze takes spray and thins; a termination tucked under an eave stays damp. Neither is an installation fault on day one and both are a problem in five years.
Air
A gas unit in a closet needs combustion air. In condominium stock the louvre is often the only opening, and blocking it for storage is the most common defect found.
The discharge
Outdoors, six inches to two feet above grade or over a receptor with an air gap, in pipe no smaller than the valve outlet. Not into a drain, and not into the alley.
Sizing
For 2.4 people, 40 gallons is usually right. A larger tank does not fix a recovery problem, it just delays the discovery.
Permit and access
The City of Oceanside's building department. Alley access and garage parking are confirmed before the day.