Installation here is settled by two facts about the housing: the households are the largest in this coverage, and many homes are two storeys with the heater at one end.
Capacity, from the household
At 2.9 people per household, a 50-gallon tank is the ordinary choice and a 40 is the exception. Bathrooms, a tub and a laundry matter more than floor area, and recovery rate matters as much as volume for a family that showers in sequence.
The run to the far tap
A second-floor bathroom at the opposite end of the plan waits for the cold slug in the pipe to clear. That is layout, not capacity, and no tank size fixes it. A recirculation loop does, and it is a separate decision with its own pump, controls and running cost.
What the install must satisfy
The flue at the clearance its listing demands, plus combustion air for a gas unit. Strapping at upper and lower thirds, the lower four inches or more clear of the controls. A relief discharge outside, six inches to two feet above grade or over a receptor with an air gap, in pipe no smaller than the valve outlet. A pan and drain where a leak could reach the structure.
Inland heat
A garage unit runs warm for months. Insulation and placement are worth a thought at installation: the same tank lasts longer in a shaded corner than against a west-facing wall.
Permit
The City of Lake Forest, against the property. Confirm the route with Building and Safety.
What to prepare
Household size, the tap that waits longest, and the vent's current route.