Installation is decided before the box is opened: capacity from the household, position from the enclosure, and venting from where the flue can legally terminate. On this side of the hills, the enclosure is usually the constraint.
Position and air
A garage wall, an exterior closet under a stair, or a purpose-built utility bay. Exterior closets are common here and they raise two questions at once — combustion air in, exhaust out. A solid door with no vent and a short flue is the pairing that produces intermittent shutdowns months later. Louvred panels, dedicated air openings or a direct-vent unit are the usual answers.
Venting on a windy site
At this elevation the wind is stronger and the marine layer thinner than on the flats, so flue behaviour varies with the weather. Termination height, clearance to windows and doors, and the model's own vent category decide whether the installation drafts reliably on a gusty October afternoon. A flue left from an older tank is not automatically suitable for a different unit.
Capacity and the long run
Detached houses here spread the demand across more fixtures and more pipe. Sizing comes from bathrooms, tubs, laundry and simultaneous draw; the run length decides whether a recirculation loop is worth considering. That loop is a separate decision with its own pump, its own failure mode and its own energy cost.
The code items
Two requirements are checked on every new installation in the state: banding in the upper and lower thirds, the lower band clear of the controls, with a third at mid-height on a 75-gallon tank; and a relief discharge that terminates outside, six inches to two feet above grade, in pipe at least the valve outlet's size. Where the discharge currently runs into a planter or uphill, the install corrects it.
For a garage, the Irvine clear-parking rule applies to the garage's usable bay.
Permit
The jurisdiction follows the parcel, not the ZIP name: inside the city, the online residential permit handles a same-location swap; outside, the county process applies. A new location or a fuel change generally moves to plan check either way.
What the day costs
Equipment by capacity and fuel sets the top line. Venting and gas work are where an installation surprises: a flue that must be replaced, a gas line that needs upsizing for a tankless unit, a condensate route that does not exist. Access on a slope adds labour, and code corrections add hours. The permit and inspection are fixed.
Before the visit
Photograph the data plate of the old unit if there is one, clear the route from the street to the heater, and note where the flue currently ends. Those three details decide most of the estimate.