A storage tank on this coast is usually a gas unit of 40 to 50 gallons, in a garage where the lot allows one and in a utility room where it does not. The parts fail in a familiar order, with one local difference: the hardware above the tank ages faster than the tank.
What wears
The relief valve opens at its stamped pressure, and over time it weeps or seizes. The drain cock works in sediment and may never shut again. At the top, the nipples and unions pit in sea air and send water down the outside of the tank. The sacrificial rod gives itself up so the wall does not. On electric units, elements and thermostats; on gas, the thermocouple, igniter and gas valve.
Pressure on a stepped lot
Where a regulator controls incoming pressure — ordinary on hillside supply — the system is closed. Heated water expands with nowhere to go, so the relief valve becomes the outlet. Which explains a valve that seems to fail twice in twelve months. An expansion tank sized for the system, plus a regulator check, addresses the cause; a fresh valve alone repeats it.
The shell decides
Once water breaches the shell — a seam, the wall, the base — repair is over. Everything above can be renewed; what is left to weigh is the life remaining in the vessel.
What a repair should cover
The part itself, the discharge termination, the strapping, the inlet valve overhead, and — on a tank past its first years — the anode. In sea air, the vent cap belongs on the list too.
Cost
Parts are minor; the trace, the draining and the access are the bill. On a stepped lot, access is rarely quick.