Most Aliso tanks are 40 or 50-gallon gas units in a garage or closet, with electric units in the apartment stock. The failures are familiar; what differs here is how often the person reporting one has no idea how old the unit is.
The parts that go
The relief valve releases at its rating and can weep or stick. The drain cock at the base works in sediment and often will not shut once opened. Top connections corrode and track water down the shell. The anode is consumed so the steel is not. On an electric unit the elements and thermostats wear; on a gas one it is the thermocouple, igniter and gas valve.
The shell is the dividing line
Once water comes through the shell — a seam, the wall, the base plate — repair has run out of road. Everything above that line can be renewed; what is left to weigh is how much service life the vessel has to justify it.
Pressure on a closed system
Where a regulator controls incoming pressure, heated water expands with nowhere to go and the relief valve becomes the outlet. That is why the same valve can appear to fail twice in a year. An expansion tank sized for the system, plus a regulator check, treats the cause; a fresh valve alone does not.
What a repair should cover
The failed part, the discharge termination, the bands, the shut-off valve above the unit and, on a tank more than a few years old, the anode. Those checks separate a repair from a repeat visit.
Cost and the comparison
Parts are modest; diagnosis, draining and access are the bill. A valve and thermostat on a six-year-old tank buys years of service. The same list on a fourteen-year-old tank buys months, and the replacement still arrives.