On a canyon property the water supply is usually on site — a well, a pump and a pressure tank — so a leak is a system question, not just an appliance question.
Shut down
Inlet valve on the cold side. If it will not close, the pump or its breaker, and the pressure tank's isolation valve where there is one. Then the fuel or the element.
Where it is coming from
Dry the unit and watch with a hot tap open. At the spout: the relief valve. At a top fitting: a union or a nipple, and sediment wear makes those fail early. At the seam or the base: the vessel.
Pressure
The pressure tank's air charge sets the static pressure in the house. Set high, it works every joint and the relief valve continuously. Checking it is part of the visit, not an extra.
Sediment
Well water carries fines that settle in the tank and grind at valve seats. A drain cock that will not close after flushing is the typical result.
The tank
Water through the shell ends repair. On a property this far out, the decision weighs a haul-out and the drive against another season.