A hillside property changes the first question on a leak call. In a flat subdivision the puddle sits under the heater; here the water picks a direction and takes it — through a floor assembly, along a slab edge, out of a wall at the low side of the house. The heater can be a storey above the water you are standing in.
Finding the source on a slope
Start at the heater, not at the puddle. The unit in this ZIP usually sits in a garage at street level, in an exterior closet, or in a utility space tucked under a stair, and each has its own usual suspects.
At the top of the tank. Nipples and dielectric unions corrode, and water runs down the shell to appear at the base — the classic false "tank leak" on a unit that is fine.
Through the relief valve or its pipe. The temperature-and-pressure valve releases at its rating, or fails to reseat. Water at the discharge pipe means the valve is doing its job or cannot close, and the pressure behind it needs a look.
At the drain valve. Sediment collects at the base, and a valve that has not moved in years may not close once it does.
Through the shell or base plate. The one finding that ends repair.
Nowhere at all. Condensation on a cold tank or on uninsulated runs in an exterior closet produces water without a failed part, especially in winter.
What repair covers
Replacement of the failed component and the correction around it: a relief valve and its discharge piping, a drain valve, unions and nipples, an element gasket, or a corroded section of pipe. Because the unit may be in a weather-exposed closet, the visit also looks at what the exposure has done to the fittings.
Two requirements usually appear while the unit is open. The discharge line has to end outside, between six inches and two feet above grade, in pipe at least the size of the valve outlet — a run that stops in a planter or above the foundation does not pass. And the tank has to be banded in its upper and lower thirds against earthquake movement.
When the shell decides it
Water through the tank wall or up through the base ends the discussion. So does a tank near the end of its service life that needs a repair costing a large share of a new unit. Storage tanks commonly reach eight to twelve years; the harder imported share of the district's water shortens that through scale.
What the bill depends on
The part is the smallest line. Access, the condition of the shut-off valve, whether the discharge has to be rerouted, and whether the pan or the enclosure has to be opened up decide the rest. A garage unit with space around it is a short visit; an exterior closet packed against a wall is not.
Before the visit
Close the inlet valve on top of the tank, cut the power or gas, and note which level the water reached. On a sloped lot that single detail tells the technician more than the size of the puddle.