T&P Valve Leaking: Is the Tank Done or Just the Valve?
A leaking T&P valve is usually reporting a problem rather than being one. Here is how to tell which, before you buy a valve.
A temperature and pressure relief valve has one job: open before the tank does. When it leaks, the useful question is not "which valve do I buy" but "what is it reacting to".
Two triggers, two patterns
Pressure. The valve opens at a set pressure, usually 150 psi. On a closed system — one with a regulator or a check valve that stops water flowing back to the main — heated water has nowhere to expand. Pressure climbs every time the burner runs, and the valve lifts a little each cycle.
The signature: steady dripping, often overnight, with a discharge that is warm but not hot.
Temperature. The valve also opens near 210°F. A thermostat stuck on, or a gas control that will not modulate, overheats the water and the valve opens to prevent a steam event.
The signature: discharge after a heating cycle, and the water is hot.
The valve itself
Sometimes it really is the valve — a seat worn by years of service, or sediment caught under it after a flush. A valve that weeps once after a drain and refill is often just debris, and lifting the lever briefly clears it.
What to check before replacing anything
Test the system's static pressure with a gauge on a hose bibb. Above roughly 80 psi, the pressure is the story. Look for an expansion tank: if there is none on a closed system, that is the answer, and it is a far smaller job than a tank replacement.
If an expansion tank exists, check its air charge. A failed bladder leaves the system with no cushion, which produces exactly the same symptom.
The reassuring part
A leaking relief valve is almost never the tank. Water through the steel is a different failure, and it shows at seams and the base plate rather than at the discharge.
Where the valve is old and the pressure is normal, a valve replacement closes the matter. Where pressure is the cause, expansion control does — and the valve is left alone.