No Hot Water and a Leak at the Same Time
No hot water plus a leak is a smaller set of causes than either alone. Here is how to narrow it in a few minutes.
Two symptoms at once is often easier to diagnose than one, because the pair rules things out.
The tank has failed
A split tank drains itself. What is left in the bottom never reaches the outlet, so every tap runs cold, and the water on the floor explains where the rest went.
The confirming signs: water at a seam or the base plate, a tank that is heavy but not full, and a leak that continues after the inlet is closed.
The relief valve is stuck open
A valve that will not reseat dumps hot water continuously. The tank refills with cold, and the outlet runs cold — while water runs at the discharge.
The confirming sign: the leak is at the discharge pipe, and it stops when the inlet is closed.
A leak plus an unrelated heating fault
Less common but real: a fitting weeps, and separately the element, thermostat or pilot has failed. This is worth ruling out, because replacing a tank for a weeping union is an expensive error.
Check the easy half first. On gas, does the pilot light? On electric, has the breaker tripped, and is any tap warm? If the answer is no to both, the heating side has failed independently.
The order to do things in
- Close the cold inlet.
- Cut the gas at the control or the breaker.
- Keep clear of standing water near wiring.
- Then diagnose.
What it usually is
In most homes, a tank failure explains both. The data plate settles the argument: a tank at ten years or more with water through the shell has no repair.
While the supply is off, emergency help is about containment rather than repair, and the leak diagnosis page covers the four sources in detail.